Module cho đầu báo thường 1 zone NOHMI FRRU004-CIZM4
– The Conventional Initiating Zone Module (FRRU004-CIZM4) is used to supervise the status of conventional initiating devices connected on an Initiating device circuit (IDC). The FRRU004-CIZM4 detects an alarm condition and reports to the Fire Alarm Control Panel (FACP). The FRRU004-CIZM4 module also supervises the initiating device wiring (A+, A-, B+, and B- wires) and wiring for the power supply connected to terminals 24+ and 24- to detect an open circuit. IDC wiring style is applicable to the NFPA Class B (Style B) & Class A (Style D). When the FRRU004-CIZM4 module detects an alarm, the module is latched until the system reset. When the FRRU004-CIZM4 module is used with Class A (Style D) wiring condition and detects an open circuit on wiring of the IDC and power supply connected to terminal 24+ and 24-, the module is also latched until the system reset.
– The FRRU004-CIZM4 module has one red LED for local indication of the statuses of module itself and its wiring. Normal conditions are indicated by flashing LED. Alarm condition is indicated by constant illumination. Open circuit condition is indicated by extinction.
Features
– One simple LED for status indication.
– NFPA Class A (Styles 6 & 7) and Class B (Style 4) for SLC.
– NFPA Class A (Style D) and Class B (Style B) for IDC.
– Electronic address setting.
– Downsized unit.
– Easy installation.
Đặc tính kỹ thuật

Model

FRRU004-CIZM4

Rated voltage range of SLC input power (S+,S-)

22.0 to 24.0V

Maximum SLC 24 VDC standby current (S+,S-)

250µA

Maximum SLC 24 VDC alarm current (S+,S-)

1mA

Operating voltage of external power supply line (24+,24-)

24V

Output voltage range of IDC (A+,A-,B+,B-)

15.7 to 22.6V

Maximum module standby current of IDC 24 VDC (24+,24-)

8.5mA in Style B, 4.9mA in Style D

Maximum detector standby current of IDC 24 VDC (24+,24-)

2.4mA

Maximum module and detector alarm current of IDC 24 VDC (24+,24-)

50.0mA

Applicable IDC wiring style

Class A (Style D), Class B (Style B)

Maximum wiring resistance of IDC

100Ω

Maximum wiring capacitance of IDC

1µF

End-of-line resistor for IDC in NFPA Style B wiring

5.1kΩ, 1/2W

Maximum alarm reset voltage

0V

Minimum alarm reset time

1.1 second

Operating temperature range

0°C to 49°C (32°F to 120°F)

Operating humidity range

0 to 93% (non-condensing)

Dimensions

106mm (4.17 inches) (H) × 106mm (4.17 inches) (W) × 29mm (1.14 inches) (D

Applicable electrical box for installation

North American 64mm (2-1/2 inches) deep 2-gang box
Standard 4 inches square box 38mm (1-1/2 inch) deep box

Chia sẻ đánh giá của bạn!

Viết đánh giá về sản phẩm...

Đánh giá của khách hàng

Chưa có đánh giá nào cho sản phẩm này.

×

Đăng nhập

Continue as a Guest

ĐĂNG KÝ NHẬN TIN KHUYẾN MÃI HOT MỖI NGÀY

Đừng bỏ lỡ hàng ngàn sản phẩm từ chương trình siêu hấp dẫn


    Chi Tiêu Hiệu Quả

    Đa dạng sản phẩm và dịch vụ Chất lượng cao với giá ưu đãi

    An Tâm Khi Mua Sắm

    Sản phẩm, hàng hóa chính hãng Thanh toán tiện lợi

    Dịch Vụ Chu Đáo

    Giao hàng nhanh trong 24h Hotline phục vụ cả T7 và CN

    0914348397
    challenges-icon chat-active-icon