Tủ Trung Tâm Báo Cháy 4 Zone SFP-2404E Notifier
Liên hệ
Features
• Four Style B (Class B) Initiating Device Circuits (IDCs).
• Two Style Y (Class B) NACs.
• Optional module that converts all four IDCs and two NACs to
Class A operation.
• 24 VDC.
• i³™ Technology features:
– Drift compensation automatically adjusts detector sensitivity and increases resistance to false alarms caused by dust
accumulation.
– Maintenance Alert LEDs (per zone) warn of excessive dirt
accumulation, preventing false alarms (meets NFPA 72
requirements).
– Detector sensitivity is automatically measured by the
detector, which automatically adjusts its sensitivity back to
the factory settings when it becomes more sensitive due to
contaminants settling in the chamber.
– Wireless handheld sensitivity meter eliminates the need for
voltmeters, magnets, and a physical connection to the
detector. The reader displays sensitivity in terms of percent
per foot obscuration and provides text status indication.
– Supervisory LED (per zone) provides warning if a detector
senses temperature approaching freezing.
– Special test protocol and LED indication allows quick test of
all detectors without need for a ladder.
• NAC synchronization features:
– Synchronization of standard ANSI audible signals as
required by NFPA 72.
– Synchronization of ADA compliant strobes per NFPA 72.
– Selectable for System Sensor, Wheelock, and Gentex
protocols.
– Selective Silence feature for manual silence of horns
while strobes continue to flash on the same NAC.
– Alarm verification selectable for each zone.
– Disable switches provided per zone.
• NACs programmable for:
– Silence Inhibit
– Auto Silence
– Strobe Synchronization
– Selective Silence (horn-strobe mute)
– Temporal or Steady signal
– Silenceable or Nonsilenceable
• Silent or audible Walk Test operation mode commanded from
the front keypad, with automatic return-to-normal after one
hour of inactivity.
• Each zone may be programmed for supervisory or fire; each
zone has separate red and yellow LEDs.
• Zone 4 is programmable for combination of tamper supervisory monitoring and waterflow alarm.
• Form-C Alarm, Trouble, and Supervisory relays.
• 3.0 A total usable current.
• 6.0 A total usable current available with optional second
transformer.
• Control buttons:
– ACK (Acknowledge)
– Alarm Silence
– Reset
– Walk Test
– Zone Enable/Disable (one per zone)
• LED indicators: – Fire Alarm (one per zone)
– Supervisory (one per zone)
– Trouble (one per zone)
– Maintenance (one per zone)
– AC Power
– NAC Disable
– Zone Disable
– NAC Fault
– System Trouble
– Power Trouble
– Walk Test
– Alarm Silence
– Earth Fault (on circuit board)
– Battery Fault (on circuit board)
– Charger Fault (on circuit board)
• Piezo sounder for alarm, trouble, supervisory and maintenance.
Specifications
AC POWER — TB3
• SFP-2404: 120 VAC, 50/60 Hz, 2.3 A.
• SFP-2404E: 240 VAC, 50 Hz, 1.15 A.
• Wire Size: Minimum 14 AWG (2.0 mm²) with 600 V insulation.
BATTERY (SEALED LEAD-ACID ONLY) — J8
• Maximum charging circuit: normal flat charge 27.6 VCD @
0.8 A.
• Maximum battery charger capacity: 18.0 AH battery (two
7.0 AH batteries can be housed in the FACP cabinet. Larger
batteries require a separate battery box such as the Notifier
BB-17).
Listings and Approvals
• UL Listed: S635
• MEA: 297-01-E Vol. II
• CSFM: 7165-0028:220
Download Catalogue:
Tủ Trung Tâm Báo Cháy 4 Zone SFP-2404E